Article - CS172773

Creo View Adapters 3.0: $ERROR Failed to register Windchill server with error "Failed to register Windchill server "https://" "TempWorkSpaceName" -- 22"

Modified: 22-Oct-2021   


Applies To

  • Windchill PDMLink 9.1 to 11.0
  • Creo View Adapters 1.0 to 3.1
  • ProductView Adapters and Creo Elements/View Adapters 12.1 to 13.0
  • Creo Parametric 1.0 to 3.0
  • Visualization Services (WVS)
  • Adapter for Creo Parametric

Description

  • Worker fails to publish with Publish Monitor error:
Failed to register Windchill server with error "Failed to register Windchill server "https://<ServerURL>" "TempWorkSpaceName" -- 22
  • Worker log reports:
proe2pv Error:56113: Failed to register Windchill server "https://<ServerURL>" "TempWorkSpaceName" -- 22
  • The uwgm.log reports:
E: uwgm.session0.1: ServerCache: Server cache schema was not found.
E: uwgm.session0.1: ServerCache: Failed to load server cache.
  • In Windows task manager, there are multiple xtop.exe processes.
  • The Creo process the visualization server keeps starting in a loop until it reaches 99% memory and then fails, always needing to manually kill the process and restart the worker.
This is a printer-friendly version of Article 172773 and may be out of date. For the latest version click CS172773