Article - CS172773
Creo View Adapters 3.0: $ERROR Failed to register Windchill server with error "Failed to register Windchill server "https://" "TempWorkSpaceName" -- 22"
Modified: 22-Oct-2021
Applies To
- Windchill PDMLink 9.1 to 11.0
- Creo View Adapters 1.0 to 3.1
- ProductView Adapters and Creo Elements/View Adapters 12.1 to 13.0
- Creo Parametric 1.0 to 3.0
- Visualization Services (WVS)
- Adapter for Creo Parametric
Description
- Worker fails to publish with Publish Monitor error:
Failed to register Windchill server with error "Failed to register Windchill server "https://<ServerURL>" "TempWorkSpaceName" -- 22
- Worker log reports:
proe2pv Error:56113: Failed to register Windchill server "https://<ServerURL>" "TempWorkSpaceName" -- 22
- The uwgm.log reports:
E: uwgm.session0.1: ServerCache: Server cache schema was not found. E: uwgm.session0.1: ServerCache: Failed to load server cache.
- In Windows task manager, there are multiple xtop.exe processes.
- The Creo process the visualization server keeps starting in a loop until it reaches 99% memory and then fails, always needing to manually kill the process and restart the worker.
This is a printer-friendly version of Article 172773 and may be out of date. For the latest version click CS172773