Article - CS163200
Measurement values are not correctly propagating to a Product Measurement Set after Re Applying Grade Rules in FlexPLM 9.2 M010
Modified: 22-Aug-2016
Applies To
- FlexPLM 9.2 M010
Description
Measurement values are not correctly propagating to a Product Measurement Set after Re Applying Grade Rules

- Matching POM (Points of Measure) name from Product measurement set does not bring measurement values from Grade Rule Template
- Steps to Reproduce:
- Create a Product Size definition with values - XS, S, M, L, XL, 2X, 3X, 4X, 5X (Base Size - M)
- Create a POM in measurement library as below with name - POM X" From Top

- Create a Measurement Template using above POM –

- Now create Incremental Grade Rule Template as below – TestGR007
- Add above POM to grade rule template
- Change POM name to POM 5 1/2" From Top (replace X with 5 1/2) as shown below and add increment by – 1.25

- Provide measurement values as below – Base Size - M – 15.000

- Save & Check in the Grade Rule template
- Navigate to Product Measurements tab and create a Product Measurement Set using above size definition, Measurement template and Grade Rule template
- On Re-Apply Grade Rules, message appears as “No grading POM found for number” (in logs) when using POM X" From Top because POM name doesn't match with POM name in Grade Rule Template
- If user changes the POM name in Measurement set to POM 5 1/2" From Top, and reapply grade rules, measurement set shows below values –


- Expected Behavior:
- Here the grade rule display mode shows correct values however measurement set does not
- On Re-Apply Grade Rules, system should pull the Measurement values when POM Name/Number are matching
- Observed Behavior:
- On Re-Apply Grade Rules, system does not pull the Measurement values when POM Name/Number are matching
This is a printer-friendly version of Article 163200 and may be out of date. For the latest version click CS163200