Article - CS103377
The amount of entries waiting to be processed in the <QueueName> queue exceeds the threshold in Windchill PDMLink
Modified: 06-Aug-2025
Applies To
- Windchill PDMLink 9.1 to 12.1
Description
- The following warning is issued by the JMX framework (thrown in the Method Server log or sent via JMX notification):
The amount of entries waiting to be processed in the <QueueName> queue exceeds the threshold: Class: class javax.management.Notification Message: There are <x> queue entries waiting to be executed in queue <QueueName> SequenceNumber: 421 Source: com.ptc:wt.subsystem=Monitors,wt.monitorType=Queues,Name=WfScheduleQueue TimeStamp: <TimeStamp> Type: wt.queue.QueueWatcherMBean.exceededWaitingEntriesThreshold UserData: <WaitingReadyEntries> - <QueueName> denotes the name of the queue, e.g. WfPropagationQueue
- Administrators receive notifications every minute