技術文章 - CS212742

Updating Line Number of one of the occurance in structure using Import From Spreadsheet is failing in Windchill PDMLink 10.2 M030

修改時間: 02-Aug-2017   


套用到

  • Windchill PDMLink 10.2 to M030-CPS05

描述

  • Updating Line Number of one of the occurance in structure using Import From Spreadsheet is failing
  • User is not able to update Line Number of one of the occurrence in the structure using Import From Spreadsheet functionality
  • Steps to Reproduce:

1. Create a structure like below

Part01
|__Part02 (Reference Designator:01, LineNumber: 01)
|__Part02 (Reference Designator:02, LineNumber: 02)

2. Export to importable spreadsheet and Import the same spreadsheet with below entries

Action   Level   Number   ReferenceDesignator   LineNumber UFID
0         Part01      
Add      1         Part02      01                              100         <Keep same>
Add      1         Part02      02                                 02         <Keep same>

3. Expected Result:

Structure should be updates as below
Part01
|__Part02 (Reference Designator:01, LineNumber: 100)
|__Part02 (Reference Designator:02, LineNumber: 02)

4. Actual Result:

Validation fails with message "The reference designator value, "<value>", must be same within sub-assembly"

This is a PDF version of Article 212742 and may be out of date. For the latest version CS212742