Статья - CS289128
Unchanged Alternates/Substitute Parts and Reference Designators are not published to Windchill Enterprise System Integration after BOM Modification
Modified: 16-Nov-2020
Относится к
- Windchill Enterprise Systems Integration 7.0 to 12.0
Описание
- Alternates/Substitute Parts and Reference Designators are not published to Windchill Enterprise System Integration (ESI) after BOM modification
- Scenario:
- Create BOM Structure with Parent Part and Child Part 1 and Child Part 2
- Add Part Substitute to Child Part 2
- Publish to ESI
- The Substitute appears in tag AddedSubstitutes
- Revise Parent Part and Child Part 1
- Publish to ESI
- The Substitute does not appear anymore in XML file generated
Это PDF-версия статьи 289128, которая может быть устаревшей. Для последней версии нажмите https://www.ptc.com/ru/support/article/CS289128